Contact Us Home Home

UV Monitoring Appliance UV_Controller_1

FeaturesUV CONTROLLER 1

The UV_Controller_1 module was specifically developed to monitor the power output of ultraviolet emitting luminescent lamps.

It features a high precision photodiode input amplifier, two customer adjustable switching points as well as a relay output.

This module can be easily mounted to panels requiring just a rectangular mounting hole according to DIN 43700. For simplified mounting and replacing we use a pluggable screw terminal system.

Supply voltage range 12 V - 18.0 V DC with surge and polarity protection

Low power consumption:( < 0.5 W @ 24 V DC)

Measurement range (photocurrent): 0 - 500 nA

3 LED display for actual intensity and state indication

Integrated warm up delay to overcome starting problems

Indication of wrong set points and over current

Switching levels (adjustable): 0 - 100 %

Measurement range (photocurrent): 0 - 500 nA

Relay output 250 V AC / 2 A free floating Silicon Carbide based chip for extreme irradiation hardness

Important Notes

Please consider any possible action to protect the sensitive photodiode input against electrostatic discharge (ESD). Not to do so may damage the appliance and voids warranty.

Please also check that there is no ground loop on the photodiode input connection as this may give wrong measurements.


Physical Dimensions

Panel width x height (mm)

96 x 48

Module depth (mm)

63

Mounting hole width x height (mm)

92 x 45

Absolute Maximum Ratings

Exceeding these limits may decrease lifetime or destroy the module or parts of it immediately.

Operation Temperature range* (ºC): 0 - +70

Storage Temperature range *: -25 - +85

Supply voltage (DC)(V): 30

Relay contact voltage (V)(AC): 250

Relay switched current (A)(AC): 2

*in non condensing environment only

Electrical Characteristics

(at 25ºC unless otherwise stated)

min, typical, max

Supply voltage (V): 11, 24, 30

Power dissipation (W) : 0.1, 0.4, 0.5

(at 24V supply voltage, depends on relay & LED state)

Analogue Signal

Photocurrent range* (nA): 0 - 500 (typical)

Low/high set point (% max photocurrent): 0 - 1500 (typical)

Hysteresis on both set points (%): 2.3, 2.43, 2.5 (min, typical, max)

*the corresponding optical power and optical power density strongly depends on the specific spectra of your UV lamp and therefore has to be calculated for each particular application.


Ordering Information

UV_Controller_1

 UV Monitoring appliance

Data Sheet

PDFUV_Controller_1 data sheet - pdf (58K)

Home | Products | Newsletter | Representatives | Contact