Contact Us Home Home

UV_DVGW_C probe - Series UV_DVGW_C

FeaturesUV-DVGW_cable

Probes from the UV-DVGW series are designed to measure and monitor irradiance levels in UV water purification facilities. The sensor fulfills the latest rules of DVGW (W294 part 3, 2006). The probe is fitted with a Silicon Carbide UV photodiode which guarantees extreme radiation hardness.


For UVC measurements only, e.g. for purification control, spectral sensitivity according to DVGW W294-3

Filtered silicon carbide (SiC) based UV detector for extreme radiation hardness

Stainless steel housing with 10 bar water pressure resistance




The UV_DVGW_C series of probes is available in the following five designs.

Part Number

Description

UV_DVGW_C_AMP4-20mA_cable

With 4-20 mA output and 2 m cable

UV_DVGW_C_AMP4-20mA_plug

With 4-20 mA output and 5 pin connector

UV_DVGW_C_AMP0-5V_cable

With 0-5 V output and 2 m cable

UV_DVGW_C_AMP0-5V_plug

With 0-5 V output and 5 pin connector


UV_DVGW_C_AMP4-20mA_cable

Integrated amplifier with 4-20 mA output

Adjustable offset and amplification factor

2 m shielded cable

UV_DVGW_C_AMP4-20mA_plug

Integrated amplifier with 4-20 mA output

Adjustable offset and amplification factor

5 pin sensor connector (connection type Hirschmann ELKA 5012)

Customised cable available

UV_DVGW_C_AMP0-5V_cable

Integrated amplifier with 0-5 V output

Adjustable offset and amplification factor

2 m shielded cable

UV_DVGW_C_AMP0-5V_plug

Integrated amplifier with 0-5 V output

Adjustable offset and amplification factor

5 pin sensor connector (connection type Hirschmann ELKA 5012)

Customised cable available

Ordering Information

UV_DVGW_C_AMP4-20mA_cable

 UV-DVGW probe with UVC photodiode according to DVGW W 294-3, with 4-20 mA output and 2 m cable.

UV_DVGW_C_AMP4-20mA_plug

 UV-DVGW probe with UVC photodiode according to DVGW W 294-3, with 4-20 mA output and 5 pin connector.

UV_DVGW_C_AMP0-5V_cable

 UV-DVGW probe with UVC photodiode according to DVGW W 294-3, with 0-5 V output and 2 m cable.

UV_DVGW_C_AMP0-5V_cable

 UV-DVGW probe with UVC photodiode according to DVGW W 294-3, with 0-5 V output and 5 pin connector.

Data Sheets

PDFUV_DVGW_C_AMP4-20mA_cable data sheet - pdf (364K)

PDFUV_DVGW_C_AMP4-20mA_plug data sheet - pdf (220K)

PDFUV_DVGW_C_AMP0-5V_cable data sheet - pdf (364K)

PDFUV_DVGW_C_AMP0-5V_plug data sheet - pdf (221K)

Home | Products | Newsletter | Representatives | Contact | Website Policies